• Temperature converter DT-8832 (one in, two out)
  • ABS series plastic-case structure supply voltage :20 ~ 35V DC
The isolated safety grid receives the input of thermal resistance, thermocouple and mv signal from the danger zone, and the output signal is converted into 4~20mA according to the configuration range and transmitted to the safety side. It has the function
Share this post to:
  • PRODUCT DETAILS
  • The isolated safety grid receives the input of thermal resistance, thermocouple and mv signal from the danger zone, and the output signal is converted into 4~20mA according to the configuration range and transmitted to the safety side. It has the function of cold end automatic compensation, and the user can customize any signal type and range that can be supported within the maximum range.

  • TECHNICAL PARAMETERS
  •  Basic parameters


    Power Supply

    20~35V DC

    Power protection

    Power backconnect protection

    Consumption current (24V power supply, 20mA output)

    ≤75mA

    Response Time

    ≤500ms 90% of the final value

    Conversion accuracy (20℃, 4~20mA)

    See Table 2 for details (excluding cold end compensation errors).

    Cold end compensates for accuracy

    ±1℃(Automatic compensation

    Temperature drift(-20℃~+60℃)

    0.005%F.S./℃

    The use of ambient temperature

    -20℃~+60℃

    Connected field equipment and the area where it is located

    Pt100, Cu50, Cu100, T, E, J, K, N, R, S, B thermocouple, millivolt signal sensor; Zone 0, zone 1, zone 2, ⅡA, ⅡB, ⅡC, T4 ~ T6 danger zone

    Hazard side input


    Input Signal

    See Table 2 for details.

    Voc

    ≤28V

    Safe side output


     IOUT

    4~20mA

    load resistance

    RL≤450Ω

    Output Impedance

    ≥1MΩ